Features
It adopted a low-temperature catalytic combustion system and a heat exchanger for efficient deodorization of odorous gas.
・Low-priced compact design
・Required utility is only electric.
・Standard equipment includes fan inverter to control wind volume.
・It becomes mobile by attaching casters.
・Air in a cabinet is ventilated with a exhaustion fan and outside temperature also remains low.
※When a concentration level of gas exceeds an explosive risk limit or gas generates heat of 200℃ or higher, such highly-concentrated gas is not treatable.
※Non-explosion proof
Usage
・VOC emission treatment and deodorization for low volume air
・Laboratory tests at universities and research institutes, draft exhaustion
・Ventilation of experimental animal rooms
・Exhaustion from a dryer and a storage
Odor decomposition reaction
CmH2n+O2 → mCO2+nH2O
Main specifications
MD model | Model | MD-2 | MD-4 | MD-6 | MD-10 |
---|---|---|---|---|---|
Processing air volume | m3/min | 2 | 4 | 6 | 10 |
Dimension (mm) |
W | 600 | 700 | 800 | 1000 |
D | 1500 | 1600 | 1900 | 2350 | |
H | 1500 | 1500 | 1800 | 2000 | |
Heater capability (standard) | 8Kw | 16Kw | 24Kw | 40Kw | |
Power supply AC200V 3 phase 50/60Hz | 40A | 75A | 100A | 150A |
Please consult our sales department for requests for models to process catalyst poisoning gas
(halogen compound, sulfur compound, phosphor compound, organosilocon and heavy metal compound),
acid gases, gas with dust or mist, high-temperature gas, PPV (positive-pressure ventilation)
model and outdoor installation models.
[Options] Mist filter, Gas concentration sensor alarm, automatic dumper, and multiple voltages
※Please contact and consult us for detailed specifications.